| | | | | Goby
Goby The first ever modular and wireless system for assessing Lower Urinary Tract Dysfunctions (LUTS) that can be transported in a travel case. GO Technology delivers wireless uroflow and wireless catheter technology which is transforming the clinical approach and allows the patient to void in the privacy of the bathroom, resulting in better reproducibility and quicker testing. | |  |
GO Technology – By eliminating the cables binding the patient to traditional diagnostic equipment, the GOBY enables healthcare professionals to perform urodynamic tests reproducing real life scenario when a patient leaks. Variable Mounting Options – Goby system mounts on an IV pole, procedure chair, table, or a cart, minimizing the footprint in the procedure room. Easy to use – Similar to GPS, GOBY’s step-by-step voice commands can help walk the clinician through a complete Urodynamic study. A Selection of Reports – The Gold Standard in Urodynamics: providing comprehensive reports. Optional EMR Integration - Streamlined integration of patient profiles (ADT), appointment management and UDS study results to your existing EMR through proven HL7 Interfaces. | Goby System |
|---|
| Test Capability | Uroflowmetry, Cystometry (CMG), Pressure Flow Study, Urethal Pressure Profile, Stress Tests & Leak Point Pressures | | Standard Report Styles | Concise, Scripted, Detailed Landscape & Detailed Portrait | | Optional Accessories | UPP Puller, Infusion Transducer, Commode Chair, Uroflow Stand, Air Mouse & Remote Control | | Setup Options | Cart, Procedure Chair, IV Pole, Table Top & Travel Case |
| Goby Hub |
|---|
| Size & Weight | L = 7.3” (18.5cm) , W = 5.4” (15.2cm), H = 8.6” (21.8cm), Weight = 3.7lbs (1.7kg) | | Pump Channels | Volume (VH20), Flow (IH20) | | Accuracy & Range | Volume Range = 0 to 1500ml Accuracy = +/- 1 % FSFlow Range = 5 to 140 ml/min Accuracy = +/- 5 % FS | | Sampling Rates | 20 Hz | | Indicator Lights | Bluetooth, Connection | | Buttons | Pump Stop | | Charger | Goby Hub Charger, 12VDC, 5.0A |
| UDS Roam |
|---|
| Size & Weight | L = 4.0” (10.2cm), W = 2.8” (7.1cm), H = 1.0” (2.5), Weight = 0.3 lbs (0.1kg) | | Output Channels | 4 Pressures, 1 EMG | | Accuracy & Range | Pressure Range = -50 to 200 cmH20, Precision =+/-1% or 2cmH2O, whichever is greaterEMG Range = +/-1000uV , Accuracy = +/-6% | | Sampling Rates | Pressure = 20 Hz, EMG = 1200 Hz | | Indicator Lights | Bluetooth, Connection, Battery | | Charger | UDS Roam Charger, 5VDC, 3.0A |
| Urocap IV |
|---|
| Size & Weight | L = 6.3” (16.0cm), W = 6.3” (16.0cm), H = 2.5” (6.4cm), Weight = 0.7lbs (0.3kg) | | Output Channels | Flow, Volume | | Accuracy & Range | Flow Range = 0 to 50mL/s , Accuracy = +/-5% FS ; Volume Range = 0 to 1200mL , Accuracy = +/-2% FS | | Sampling Rates | Flow = 20 Hz, Volume = 20 Hz | | Indicator Lights | Bluetooth, Connection, Battery | | Charger | Urocap IV Charger, 5VDC, 3.0A |
| GO Cart |
|---|
| Size | L = 30.0” (76.2cm), W = 25.5” (64.8cm), H = 31”-41” (80cm-105cm) |
* Optional Tubing 
- Pump Tubing Infusion Line - PN # TUB500 - Includes all components needed to accurately infuse fluid through urodynamic catheters.

- Measurement Tubing - PN # TUB101 - Pressure measurement tubing with attached stopcock.

- Extension Tubing without Stockcock - PN # TUB576 - Extension tubing with male-male connectors.
|
| |
|
|
|